Search
Menu Close

Information - G-Link Connectors

Information - G-Link Connectors

RING OR HOOK CONNECTION

Can fail if damaged, misused or overloaded. Inspect before use. Use only if trained. Observe rated capacity. DEATH or INJURY can occur from improper use or maintenance.


END TO END CONNECTION - RATED AT SLING CHOKER CAPACITY

Using one G-Link™ on each sling (two total), this connection has a rated choker capacity of one G-Link™.

Using two G-Links™ on each sling (four total), this connection has the rated
hoker capacity of two G Links™.

Place G-Links™ with the open arms facing in the same direction and the round sides of the arms as shown. Put the slings through the closed slot of the G-Links™. Connect sling loops over the open arms.

Pull slings tight. Make sure flat sides of G-Links™ are against each other. Take slack out of the connection before use.

To make a stronger Two Sling Connection, use two G-Links™ on each sling as shown. Place flat sides of each pair of G-Links™ against each other. The half round reinforcement bars must be on opposite sides of the open arms. Attach both sling loops to the open arms of both pairs of G-Links™.

Pull slings tight. Make sure the slack is taken out of the connection before use.

SLIDING CHOKER HITCHS

Can fail if damaged, misused or overloaded. Inspect before use. Use only if trained. Observe rated capacity. DEATH or INJURY can occur from improper use or maintenance.

 

Put two G-Links™ on sling with flat sides together.

Always use two G-Links™ for this hitch.

Two G-Links™ will have the rated capacity of one G-Link™ when used this way.

Attach sling loop to G-Links™ as shown. Always use two G-Links™ for the Sliding Choker Hitch.

 

 

TWO LEG BRIDLE

The angle of the legs affects the strength of the bridle. Determine the reduced Bridle Work Load Limit (WLL) at the angle of use. 60° Horizontal Angle Reduces Work Load Limit 15%. 45° Horizontal Angle Reduces Work Load Limit 30%. 30° Horizontal Angle Reduces Work Load Limit 50%.

TWO SLING CONNECTION
See previous instructions for Two Sling connections. Make sure the inside of the Ring and Hooks are free from all damaging surfaces and edges. Make sure Rings and Hooks are of the proper size for the slings and the load.


G-LINKS™ TOP AND BOTTOM
See previous instructions for Rings and Hooks. The inside area of Rings and Hooks must be of the proper size and free from all damaging surfaces and edges. When connecting two G-Links™ to a Ring put them on opposite sides of the Ring, they will fit better.

WIDER G-LINK™ AT TOP

A single, wider G-Link™ at the top accommodates the width of both slings. Individual G-Links™ are placed at the bottom of each leg. See previous instructions for Ring and Hook connections. Top Link(s) must be wide enough and have proper rated capacity to accommodate both slings.

Can fail if damaged, misused or overloaded. Inspect before use. Use only if trained. Observe rated capacity. DEATH or INJURY can occur from improper use or maintenance.